Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.073
Filtrar
Más filtros

Intervalo de año de publicación
1.
PLoS One ; 19(3): e0297985, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38498581

RESUMEN

OBJECTIVES: We conducted a comprehensive meta-analysis to compare the effectiveness and safety of fluoroscopy-guided air enema reduction (FGAR) and ultrasound-guided hydrostatic enema reduction (UGHR) for the treatment of intussusception in pediatric patients. METHODS: A systematic review and meta-analysis were conducted on retrospective studies obtained from various databases, including PUBMED, MEDLINE, Cochrane, Google Scholar, China National Knowledge Infrastructure (CNKI), WanFang, and VIP Database. The search included publications from January 1, 2003, to March 31, 2023, with the last search done on Jan 15, 2023. RESULTS: We included 49 randomized controlled studies and retrospective cohort studies involving a total of 9,391 patients, with 4,841 in the UGHR and 4,550 in the FGAR. Specifically, UGHR exhibited a significantly shorter time to reduction (WMD = -4.183, 95% CI = (-5.402, -2.964), P < 0.001), a higher rate of successful reduction (RR = 1.128, 95% CI = (1.099, 1.157), P < 0.001), and a reduced length of hospital stay (WMD = -1.215, 95% CI = (-1.58, -0.85), P < 0.001). Furthermore, UGHR repositioning was associated with a diminished overall complication rate (RR = 0.296, 95% CI = (0.225, 0.389), P < 0.001) and a lowered incidence of perforation (RR = 0.405, 95% CI = (0.244, 0.670), P < 0.001). CONCLUSION: UGHR offers the benefits of being non-radioactive, achieving a shorter reduction time, demonstrating a higher success rate in repositioning in particular, resulting in a reduced length of postoperative hospital stay, and yielding a lower overall incidence of postoperative complications, including a reduced risk of associated perforations.


Asunto(s)
Intususcepción , Niño , Humanos , Enema/métodos , Fluoroscopía , Intususcepción/terapia , Estudios Retrospectivos , Ultrasonografía
2.
J Bodyw Mov Ther ; 37: 399-403, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38432836

RESUMEN

BACKGROUND: Ultrasonography (US) has been suggested to assess the morphology and function of cervical muscles; but little is known about the reliability of the US measures in patients with cervical disc herniation (CDH). The purpose of this study was to evaluate within-day inter and intra-rater and between-day intra-rater reliability of US to measure dimensions of deep cervical muscles in patients with unilateral CDH. METHODS: Thirty patients with unilateral CDH participated. Anterior-posterior and lateral dimension of longus colli (LC), multifidus (MF) and semispinalis cervicis (SC) were measured using B-mode ultrasound. The measurements were repeated by rater A 1 h (for within-day reliability) and one week (for between-day reliability) later. For inter-rater reliability, rater B performed all muscles measurements like rater A. RESULTS: Within-day reliability measurement for all muscles was good to excellent with IntraClass Correlation Coefficients (ICC) ranging from 0.82 to 0.96, standard error of measurement (SEM) from 0.18 to 0.46 and minimal detectable changes (MDC) from 0.43 to 1.09. Between-day reliability was good for all muscle dimensions with ICC ranging from 0.75 to 0.89, SEM from 0.30 to 0.64 and MDC from 0.71 to 1.52. Inter-rater reliability was also good with ICC ranging from 0.75 to 0.89, SEM from 0.34 to 0.65 and MDC from 0.81 to 1.55. CONCLUSIONS: US was demonstrated to have high within-day inter and intra-rater and between-day intra-rater reliability to measure muscles dimensions in patients with unilateral CDH. It can be used to assess deep cervical muscles or to monitor the effects of interventions.


Asunto(s)
Desplazamiento del Disco Intervertebral , Músculos Paraespinales , Humanos , Músculos Paraespinales/diagnóstico por imagen , Estudios Transversales , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Reproducibilidad de los Resultados , Músculos del Cuello/diagnóstico por imagen , Ultrasonografía
3.
J Bodyw Mov Ther ; 37: 90-93, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38432847

RESUMEN

BACKGROUND: Retinacula of the ankle are thickening of the deep fascia of the leg (crural fascia) and foot i.e. inseparable structures. Recent studies report their crucial role in functional stability and proprioception of the ankle. CASE PRESENTATION: A 38-yr-old Caucasian man - with a history of lateral malleolus fracture 12 years ago, obesity and right ankle osteoarthritis - was referred to a physiatrist for a right ankle pain that had significantly worsened over the last year. During walking, the patient experienced stinging pain in the area of tibialis anterior and peroneus tertius muscles, and the superior extensor retinaculum. Magnetic resonance imaging and ultrasonography showed clear thicknening (2.05 mm) of the oblique superomedial band of the inferior extensor retinaculum. Sonopalpation was performed to precisely evaluate/confirm the site of maximum pain. Foot function index (FFI) score was 42. RESULTS: Subsequently, the patient was prescribed fascial manipulation, and he had clinical improvement after the first session (FFI: 21). At 1-month follow-up, the patient was still asymptomatic without any functional limitation (FFI: 24). US imaging confirmed the decreased thickness of the oblique superomedial band of the extensor retinaculum (1.35 mm). CONCLUSION: Fascial Manipulation® appears to be a useful tool to reduce thickness, stiffness, and pain in this case as displayed by the ultrasound Imaging.


Asunto(s)
Tobillo , Osteoartritis , Masculino , Humanos , Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Ultrasonografía , Fascia/diagnóstico por imagen , Dolor
5.
World J Gastroenterol ; 30(5): 499-508, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38414592

RESUMEN

BACKGROUND: Superior mesenteric artery (SMA) syndrome is a rare cause of duodenal obstruction by extrinsic compression between the SMA and the aorta (SMA-Ao). Although the left lateral recumbent position is considered effective in the treatment of SMA syndrome, individual variations in the optimal patient position have been noted. In this report, we present two elderly cases of SMA syndrome that exhibited rapid recovery due to ultrasonographic dynamic evaluation of the optimal position for each patient. CASE SUMMARY: Case 1: A 90-year-old man with nausea and vomiting. Following diagnosis of SMA syndrome by computed tomography (CT), ultrasonography (US) revealed the SMA-Ao distance in the supine position (4 mm), which slightly improved in the lateral position (5.7-7.0 mm) without the passage of duodenal contents. However, in the sitting position, the SMA-Ao distance was increased to 15 mm accompanied by improved content passage. Additionally, US indicated enhanced passage upon abdominal massage on the right side. By day 2, the patient could eat comfortably with the optimal position and massage. Case 2: An 87-year-old woman with vomiting. After the diagnosis of SMA syndrome and aspiration pneumonia by CT, dynamic US confirmed the optimal position (SMA-Ao distance was improved to 7 mm in forward-bent position, whereas it remained at 5 mm in the supine position). By day 7 when her pneumonia recovered, she could eat with the optimal position. CONCLUSION: The optimal position for SMA syndrome varies among individuals. Dynamic US appears to be a valuable tool in improving patient outcomes.


Asunto(s)
Obstrucción Duodenal , Síndrome de la Arteria Mesentérica Superior , Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Síndrome de la Arteria Mesentérica Superior/diagnóstico por imagen , Síndrome de la Arteria Mesentérica Superior/terapia , Síndrome de la Arteria Mesentérica Superior/complicaciones , Obstrucción Duodenal/diagnóstico , Ultrasonografía/efectos adversos , Vómitos/diagnóstico por imagen , Vómitos/etiología , Tomografía Computarizada por Rayos X/efectos adversos , Arteria Mesentérica Superior/diagnóstico por imagen
6.
Nanotheranostics ; 8(2): 127-149, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38328614

RESUMEN

Cardiovascular disease is one of the chief factors that cause ischemic stroke, myocardial infarction, and venous thromboembolism. The elements that speed up thrombosis include nutritional consumption, physical activity, and oxidative stress. Even though the precise etiology and pathophysiology remain difficult topics that primarily rely on traditional medicine. The diagnosis and management of thrombosis are being developed using discrete non-invasive and non-surgical approaches. One of the emerging promising approach is ultrasound and photoacoustic imaging. The advancement of nanomedicines offers concentrated therapy and diagnosis, imparting efficacy and fewer side effects which is more significant than conventional medicine. This study addresses the potential of nanomedicines as theranostic agents for the treatment of thrombosis. In this article, we describe the factors that lead to thrombosis and its consequences, as well as summarize the findings of studies on thrombus formation in preclinical and clinical models and also provide insights on nanoparticles for thrombus imaging and therapy.


Asunto(s)
Nanopartículas , Trombosis , Humanos , Medicina de Precisión , Trombosis/diagnóstico por imagen , Trombosis/terapia , Ultrasonografía/métodos , Nanopartículas/uso terapéutico
7.
Ultrason Sonochem ; 103: 106779, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38262175

RESUMEN

Potato chips are popular high-consuming ready-to-eat meals in all of the world which specially attract a lot of attention from youth and children. Reducing oil absorption and improving the quality of chips are major undertakings within the industry. This research aimed to find the best ultrasonic bath-based method by investigating the optimal ultrasonic pre-treatment and developing an ultrasound (US) assisted frying system (UAFS) to reduce the oil absorption of potato chips while maintaining an acceptable quality. Through this technique, the potato chips get sonicated during deep frying in hot oil. US-pretreatment at temperatures of 25 °C and 73 °C, along with US-assisted frying, resulted in the minimal amount of oil which may be due to the US creating potential pores during the pre-treatment phase, which then expand further during the subsequent sonication stage. UAFS in combination with US-pretreatment produced more crispy chips due to the fact that the texture of potato slices becomes more porous. UAFS resulted in a decrease in the moisture content of the fried chips attributed to an increase in the effective diffusion coefficient and mass. Pretreating the chips at 73 °C significantly reduce the color change producing brighter product by inactivation of enzymes such as polyphenol oxidase. Finally, the result of TOPSIS optimization based on potato chips properties confirms that US-pretreatment in 73 °C brine followed by frying using UAFS is the best approach. Scanning electron microscope (SEM) images of potato chips also support this issue.


Asunto(s)
Manipulación de Alimentos , Solanum tuberosum , Niño , Humanos , Adolescente , Manipulación de Alimentos/métodos , Culinaria/métodos , Fenómenos Químicos , Ultrasonografía , Alimentos
8.
Nutrients ; 16(2)2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38257121

RESUMEN

Caffeine is present in various foods and medicines and is highly accessible through various routes, regardless of age. However, most studies on caffeine have focused on the effects of high-dose caffeine ingestion based on the recommended daily amount for adults. In this study, we examined the physiological changes in the central and peripheral vessels that may occur when ingesting low-dose caffeine due to its high accessibility, with the aim of creating an environment of safe caffeine ingestion. This study included 26 healthy participants in their 20s. Peak systolic velocity (PSV), heart rate (HR), and pulse wave velocity (PWV) for vascular stiffness assessment were measured at 0, 30, and 60 min after caffeine ingestion using diagnostic ultrasound to determine the physiological changes in the blood vessels, common carotid artery (CCA) and radial artery (RA). In addition, percutaneous oxygen saturation (SpO2), blood pressure (BP), and accelerated photoplethysmography (APG) were measured. In comparison with before ingestion, the HR tended to decrease and showed a significant difference at 30 and 60 min (p = 0.014 and p = 0.031, respectively). PSV significantly decreased in both vessels at 30 and 60 min (p < 0.001 and p < 0.001, respectively). APG showed a decreasing trend until 60 min after ingestion, with a significant difference at 30 and 60 min (p = 0.003 and p = 0.012, respectively). No significant difference was observed in SpO2, BP, or PWV; however, they showed a tendency to increase after ingestion. Decreased HR may occur because of the baroreflex caused by an increase in BP. The RA has many branches and a smaller diameter; therefore, the PSV was lower in the RA than that in the CCA. This effect can occur because of the difficulty in the smooth expansion of blood vessels, which leads to a decrease in blood flow. In addition, an increase in intracellular calcium concentration can prevent vasodilation and increase the propagation velocity of pulse waves. The reflected waves can increase systolic blood pressure but reduce PWV and vascular elasticity. These results suggest that even low-dose caffeine can improve blood vessel health by providing temporary stimulation to the blood vessels; however, it can also cause changes in blood flow and blood vessel elasticity, which can lead to serious diseases such as stroke and high blood pressure. Therefore, caution should be exercised when caffeine consumption is indiscriminate.


Asunto(s)
Cafeína , Análisis de la Onda del Pulso , Adulto , Humanos , Ultrasonografía , Arteria Radial , Ingestión de Alimentos
9.
Pediatr Emerg Care ; 40(3): 239-242, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37890187

RESUMEN

ABSTRACT: We discuss 10 cases where the qualitative evaluation of hard stool in the rectum with point-of-care ultrasound helped guide enema administration in a pediatric emergency department. Point-of-care ultrasound findings were especially valuable in cases where the presenting symptoms were undifferentiated, a language barrier was present, or the guardian and child denied that constipation was an active problem. When sodium phosphate enema administration was done in the pediatric emergency department, evacuation of the rectal stool burden was observed in most cases before final disposition.


Asunto(s)
Estreñimiento , Sistemas de Atención de Punto , Niño , Humanos , Estreñimiento/diagnóstico por imagen , Estreñimiento/terapia , Enema , Recto/diagnóstico por imagen , Ultrasonografía
10.
Chin J Integr Med ; 30(3): 203-212, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38051474

RESUMEN

OBJECTIVE: To investigate a new noninvasive diagnostic model for nonalcoholic fatty liver disease (NAFLD) based on features of tongue images. METHODS: Healthy controls and volunteers confirmed to have NAFLD by liver ultrasound were recruited from China-Japan Friendship Hospital between September 2018 and May 2019, then the anthropometric indexes and sampled tongue images were measured. The tongue images were labeled by features, based on a brief protocol, without knowing any other clinical data, after a series of corrections and data cleaning. The algorithm was trained on images using labels and several anthropometric indexes for inputs, utilizing machine learning technology. Finally, a logistic regression algorithm and a decision tree model were constructed as 2 diagnostic models for NAFLD. RESULTS: A total of 720 subjects were enrolled in this study, including 432 patients with NAFLD and 288 healthy volunteers. Of them, 482 were randomly allocated into the training set and 238 into the validation set. The diagnostic model based on logistic regression exhibited excellent performance: in validation set, it achieved an accuracy of 86.98%, sensitivity of 91.43%, and specificity of 80.61%; with an area under the curve (AUC) of 0.93 [95% confidence interval (CI) 0.68-0.98]. The decision tree model achieved an accuracy of 81.09%, sensitivity of 91.43%, and specificity of 66.33%; with an AUC of 0.89 (95% CI 0.66-0.92) in validation set. CONCLUSIONS: The features of tongue images were associated with NAFLD. Both the 2 diagnostic models, which would be convenient, noninvasive, lightweight, rapid, and inexpensive technical references for early screening, can accurately distinguish NAFLD and are worth further study.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Ultrasonografía , Antropometría , Algoritmos , China
11.
Altern Ther Health Med ; 30(1): 24-30, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37773656

RESUMEN

Objective: Exploring newer approaches to brachial plexus block is crucial for improving surgical outcomes and patient comfort. This study aims to review the application and research progress of ultrasound-guided brachial plexus block via the costoclavicular space approach in upper limb surgery. Methods: This study provides a comprehensive review of existing literature, studies, and clinical cases related to the costoclavicular approach. The advantages and disadvantages of conventional approaches for brachial plexus block, including the intermuscular groove method, supraclavicular method, and axillary approach, are discussed. The anatomical characteristics of the costoclavicular space are examined, and the methods of brachial plexus nerve block using ultrasound-guided costoclavicular space approach are described. It holds great promise for enhancing patient care and increasing the overall success rate of surgical procedures. Results: The costoclavicular space approach for brachial plexus block offers several advantages, including stable anatomical structure, low nerve variation rate, and clear visualization of each nerve bundle under ultrasound imaging. Compared to traditional approaches, ultrasound-guided brachial plexus block via the costoclavicular space approach has a high success rate, rapid onset of anesthesia, and high safety. Conclusion: Ultrasound-guided brachial plexus block via the costoclavicular space approach is effective and safe in upper limb surgery. It provides good anesthesia and postoperative analgesia, making it a valuable technique for various upper limb surgeries. The potential clinical significance of our findings lies in the possibility that ultrasound-guided costoclavicular space approach, with its enhanced precision and patient outcomes, could play a pivotal role in improving upper limb surgical procedures.


Asunto(s)
Bloqueo del Plexo Braquial , Humanos , Bloqueo del Plexo Braquial/métodos , Anestésicos Locales , Ultrasonografía Intervencional/métodos , Ultrasonografía , Extremidad Superior/cirugía
12.
Altern Ther Health Med ; 30(1): 226-231, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37773681

RESUMEN

Objective: To assess the reliability of quantitative ultrasound (QUS) in diagnosing and screening osteoporosis in elder women. Methods: We conducted a systematic search of the online databases, including PubMed, Embase, Web of Science, and China National Knowledge, and screened the studies according to the inclusion criteria. We directly extract or calculate the value of true positive (TP), false positive (FP), false negative (FN), and true negative (TN) from eligible studies. We sought to evaluate the diagnostic parameters of QUS, containing the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC). Results: Twelve studies were included in this study with a total of 2260 women. QUS showed a pooled diagnostic odds ratio of 5.07 (95% CI 3.28-7.84), sensitivity of 0.69 (95% CI 0.65-0.72), specificity of 0.67 (95% CI 0.64-0.69), and an AUC of 0.7523 (Q*=0.6953). There was no obvious heterogeneity and threshold effect according to the Spearman correlation coefficient (P = 0.059). No significant publication bias was found through the Deek's funnel. Conclusion: Our study suggested that the diagnostic value of QUS for osteoporosis in elder women was acceptable, but the accuracy still needed to be improved, QUS can be recommended as a pre-screening tool for osteoporosis to determine whether DXA measurement was needed.


Asunto(s)
Osteoporosis , Humanos , Femenino , Anciano , Curva ROC , Reproducibilidad de los Resultados , Ultrasonografía , Osteoporosis/diagnóstico por imagen , China
13.
Artículo en Inglés | MEDLINE | ID: mdl-38096645

RESUMEN

Endometriosis is a complex chronic inflammatory process characterised by the presence of endometrial-like glandular tissue outside the uterine cavity, typically within the pelvic structures. This condition affects up to 10-15 % of women and those assigned female at birth, and can result in chronic pelvic pain and in/subfertility. Treatment goals include medical, surgical options and alternative therapies. Transvaginal ultrasound (TVUS) is the currently recommended first line investigation for endometriosis with magnetic resonance imaging (MRI) reserved for those with equivocal ultrasound findings. In this paper, we aim to outline the commonly seen sonographic appearances of endometriosis divided into anterior, middle and posterior pelvic compartments. Limitations to ultrasound imaging include high operator dependence and patient factors. New imaging techniques and research into the utility of artificial intelligence (AI) into the detection of endometriosis is currently underway, with possibility of reduced diagnostic delay and better patient outcomes.


Asunto(s)
Endometriosis , Infertilidad Femenina , Recién Nacido , Femenino , Humanos , Endometriosis/complicaciones , Endometriosis/diagnóstico por imagen , Infertilidad Femenina/diagnóstico por imagen , Infertilidad Femenina/etiología , Inteligencia Artificial , Diagnóstico Tardío , Ultrasonografía/métodos , Sensibilidad y Especificidad
14.
Med Ultrason ; 25(4): 398-402, 2023 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-38150681

RESUMEN

AIM: This study aims to evaluate the educational quality of videos related to ultrasound guided dry needling (USDN). Material and method: This study was designed as a cross-sectional study. A video-based search was performed on the YouTube online video sharing platform (https://www.youtube.com/) using the English keywords "ultrasound guided dry needling" on May 10, 2023. The first 60 videos were analysed. RESULT: The first 60 videos were analyzed, and 32 videos that met the inclusion criteria were included in the study. The content of the videos mostly consisted of technical knowledge regarding Ultrasound Guided Dry Needling (USGDN) (56.3%) and information (43.84%). The total mean DISCERN score was 26.9 ± 12.0 (range 17 to 54). The total mean JAMA Score was 2.4 ± 0.7 (range 2 to 4). There was no significant differences between the groups, according to the DISCERN, and JAMAs scores (all p>0.05). The video with the highest DISCERN score belongedto The American Institute of Ultrasound in Medicine (AIUM) channel. CONCLUSION: There is a significant amount of content available on YouTube regarding USDN; however, unfortunately, most of the existing content is of low quality and carries the risk of misinformation. Healthcare professionals should be aware of the importance of health-related information on YouTubeand strive to provide high-quality, accurate, and up-to-date content.


Asunto(s)
Punción Seca , Medios de Comunicación Sociales , Humanos , Estudios Transversales , 60575 , Ultrasonografía , Reproducibilidad de los Resultados , Grabación en Video
15.
Urologiia ; (6): 145-150, 2023 Dec.
Artículo en Ruso | MEDLINE | ID: mdl-38156699

RESUMEN

Recurrent bladder neck sclerosis is one of the common complications of endoscopic treatment of benign prostate hyperplasia, which often leads to multiple re-operations, including complex open and laparoscopic reconstructive procedures. One of the most promising minimally invasive methods for preventing recurrence of bladder neck sclerosis is balloon dilatation under transrectal ultrasound guidance. To improve the results of using this technique, a urethral catheter with a biopolymer coating, capable of depositing a drug and eluting it under the influence of diagnostic ultrasound, was proposed.


Asunto(s)
Hiperplasia Prostática , Resección Transuretral de la Próstata , Obstrucción del Cuello de la Vejiga Urinaria , Masculino , Humanos , Próstata/patología , Resección Transuretral de la Próstata/métodos , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/cirugía , Catéteres Urinarios/efectos adversos , Esclerosis/complicaciones , Esclerosis/patología , Hiperplasia/complicaciones , Hiperplasia/patología , Hiperplasia Prostática/complicaciones , Obstrucción del Cuello de la Vejiga Urinaria/complicaciones , Ultrasonografía , Resultado del Tratamiento
16.
J Bodyw Mov Ther ; 36: 228-234, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949565

RESUMEN

INTRODUCTION: Foam Rolling (FR) as a technique of self-massage has become a widely used intervention in clinical and sports practice. It is assumed that FR leads to an increased intramuscular microvascular blood flow (MBF), and therefore is commonly recommended as a warm-up or regeneration method. However, no data validate the effects of FR on MBF. This study aimed to assess whether FR increases intramuscular MBF using contrast-enhanced ultrasound (CEUS). METHODS: Ten healthy athletes performed a standardized FR intervention applied to the lateral thigh (3 sets: 45 s FR, 20 s rest). Intramuscular perfusion was determined by CEUS under resting conditions (t0), immediately (t1), and 30 min (t2) after the intervention. Peak enhancement (PE), wash-in rate (WiR), and wash-in perfusion index (WiPI) were evaluated as quantitative perfusion parameters in vastus lateralis (VL) and intermedius (VI) muscle separately via regions of interest mapping. RESULTS: Immediately after the intervention (t1), perfusion parameters showed a non-significant decrease in VL (p = 0.3; PE: -32.1%, WiPI: -29.6%, WiR: -50.4%) and VI (p = 0.4; PE: -10.3%, WiPI: -6.4%, WiR: -35.6%). A non-significant decrease was found at t2 in VL (p = 0.2; PE: -34%, WiPI -33.9%, WiR -61.2%) and VI (p = 0.2; PE -17.6%, WiPI -13.8%, WiR -43.2%). CONCLUSIONS: The common assumption of intramuscular MBF improvement due to FR could not be confirmed for up to 30 min after the intervention. If an increase in intramuscular metabolism or MBF is intended, we recommend that alternative methods (i.e., traditional warm-up) should be preferred.


Asunto(s)
Medios de Contraste , Músculo Cuádriceps , Humanos , Músculo Cuádriceps/diagnóstico por imagen , Microcirculación/fisiología , Ultrasonografía/métodos
17.
J Bodyw Mov Ther ; 36: 349-356, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949583

RESUMEN

BACKGROUND: Few studies have reported on the morphometry of the subscapularis muscle using ultrasound imaging (USI); and their reproducibility has not been verified. OBJECTIVES: This study aimed to clarify the relative and absolute reproducibility of USI measurements of subscapularis muscle thickness at rest and during isometric contraction as well as the degree of change in muscle thickness caused by the amount of internal rotational torque in the shoulder joint. DESIGN: Two-group repeated-measures study. METHODS: The subjects were the inferior fibers of the subscapularis muscle of 40 healthy adult males. Muscle thickness was measured at rest and at 10%-30% of the maximum isometric internal rotation torque. Intraclass correlation coefficients (ICC) and Brand Altman analysis were used for reproducibility measurement. The degree of change in muscle thickness at each torque was also calculated. RESULTS: Intra- and inter-rater ICCs (ranged from 0.69 to 0.91) were good. A proportional error was observed in intra-rater measurements. Both minimal detectable change 95 (ranged from 2.33 to 6.47) were high. The subscapularis muscle thickness was significantly increased at 10% torque (25.49 ± 3.80 mm), 20% torque (26.07 ± 3.90 mm), and 30% torque (25.96 ± 3.82 mm) as compared to that in resting conditions (24.53 ± 4.46 mm) (p < 0.05). CONCLUSION: The reproducibility and error of the subscapularis muscle thickness measurement using USI used in this study were clarified when repeated measurements were made in the same limb position and under the same probe installation conditions, suggesting that the contraction of the subscapularis muscle can be estimated by muscle thickness measurement.


Asunto(s)
Articulación del Hombro , Masculino , Adulto , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiología , Manguito de los Rotadores/fisiología , Torque , Reproducibilidad de los Resultados , Ultrasonografía
18.
J Bodyw Mov Ther ; 36: 399-403, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949591

RESUMEN

BACKGROUND: Arthrokinematics (caudal and posterior movements of the talus) and posterior soft tissues of the ankle during ankle dorsiflexion have not been objectively evaluated in detail. This study aimed to investigate the characteristics of arthrokinematics and posterior soft tissues of the ankle during ankle dorsiflexion using ultrasound. METHODS: Thirteen healthy adults participated in the study. Participants whose passive dorsiflexion range of motion (ROM) of the ankle joint was <35° were classified as the restricted group (n = 6), and participants whose passive ankle dorsiflexion ROM was ≥35° were classified as the control group (n = 7). Passive ankle dorsiflexion was performed to measure the ankle arthrokinematics. Strain elastography was performed to measure the elasticity of the flexor hallucis longus (FHL) and Kager's fat pad (KFP) at each dorsiflexion angle. RESULTS: A significant difference in the posterior movement of the talus at the ankle dorsiflexion of 30° was observed between the two groups (P = 0.04). The elasticity of the restricted group was increased at all angles in both FHL and KFP (P < 0.05). CONCLUSION: This study showed that it is possible to objectively evaluate the direction of ankle arthrokinematics and posterior ankle soft-tissue restrictions using ultrasound.


Asunto(s)
Articulación del Tobillo , Tobillo , Adulto , Humanos , Articulación del Tobillo/diagnóstico por imagen , Tobillo/diagnóstico por imagen , Movimiento , Rango del Movimiento Articular , Ultrasonografía
19.
J Bodyw Mov Ther ; 36: 62-68, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949601

RESUMEN

OBJECTIVES: The stiffness of median nerve increases in carpal tunnel syndrome (CTS) even at mild stage of syndrome which could be regarded as a diagnostic criterion. The aim of this study was to evaluate the immediate effects of neurodynamic technique on median nerve stiffness and cross-sectional area (CSA) at wrist and elbow in individuals with CTS. MATERIAL AND METHODS: It was a quasi-experimental study. Twenty patients were recruited for this study. They were included if aged 18-65 years and diagnosed with CTS based on electrodiagnostic and clinical findings. The exclusion criteria were previous surgeries at wrist or elbow. Patients were assessed by shear wave sono-elastography before and immediately after one session of neurodynamic mobilization technique (NDM). The primary outcome measure was the stiffness of the median nerve at wrist and the secondary outcomes were nerve stiffness at elbow and CSA of nerve at wrist and elbow. RESULTS: Median nerve stiffness and CSA decreased significantly at wrist immediately after a session of NDM. These parameters also decreased at elbow but were not statistically significant. CONCLUSION: One session of NDM reduced the stiffness and CSA of median nerve at wrist in patients with CTS as detected by sono-elastography verifying that sono-elastography is able to quickly detect the immediate biomechanical changes of the median nerve.


Asunto(s)
Síndrome del Túnel Carpiano , Diagnóstico por Imagen de Elasticidad , Articulación del Codo , Humanos , Nervio Mediano/diagnóstico por imagen , Síndrome del Túnel Carpiano/diagnóstico por imagen , Muñeca/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía
20.
Lasers Med Sci ; 38(1): 248, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37906312

RESUMEN

The aim of this study was to evaluate the effects of high intensity laser therapy (HILT) on pain, functional status, hand grip strength, and median nerve cross-sectional area by ultrasonography in patients with carpal tunnel syndrome. Sixty patients who were diagnosed with carpal tunnel syndrome were included in the study. The patients observed during the research were randomly divided into two groups with 30 patients in each group. Splint+ exercise and HILT (pulsed mode with a power of 8.0 W and energy density of 8 J/cm2 for 1.40 minutes for every 25 cm2, continuous mode with a power of 3.0 W and energy density of 80 J/cm2 for 11 minutes for each 25 cm2; total 10 sessions 5 days a week) were applied for 2 weeks for the first group, and splint+exercise and sham laser treatment were applied for 2 weeks for the second group. Randomization was undertaken with the assistance of a computer-generated random number table before beginning the treatment processes. The patients were evaluated with the determined scales before the treatment, at the end of the treatment, and at the 3rd month. Hydraulic hand dynamometer was used to measure hand grip strength, visual analog scale (VAS) for pain, Boston CTS Questionnaire to assess function, and ultrasonography to measure median nerve cross-sectional area. The impact of time on the change in VAS levels was found to be of statistical significance within each group of patients (p<0.001), but between-group comparisons did not yield significant results (p<0.454). The effects of time on variations in Boston CTS Questionnaire scores were found to have been of statistical significance for both groups (p<0.001), but significance was not subsequently observed when the results of the two groups were compared on a between-group basis (p=0.226 and p=0.973 for the FSS and SSS, respectively). While time had a statistically significant effect on the change in hand grip strength for both groups (p=0.000), between-group comparisons statistical significance finding in favor of HILT was found in the early period (p=0.012). The time-group association patterns of the groups showed significant difference (p=0.025). While time had a statistically significant effect on the changes in the median cross-sectional areas of the nerve for the patients of both treatment groups (p<0.001), between-group comparisons yielded no findings of statistical significance (p=0.438). The time-group relationship patterns of the groups were found to reflect statistical significance (p=0.001). In conclusion, the results of the research presented here have confirmed that hand grip strength may increase and the median nerve's cross-sectional area may decrease upon the application of high-intensity laser for individuals experiencing CTS. However, this effect was demonstrated here only in the short-term and the evidence was not maintained through the course of follow-up of a longer duration.


Asunto(s)
Síndrome del Túnel Carpiano , Terapia por Luz de Baja Intensidad , Humanos , Nervio Mediano/diagnóstico por imagen , Síndrome del Túnel Carpiano/diagnóstico por imagen , Síndrome del Túnel Carpiano/radioterapia , Fuerza de la Mano , Estado Funcional , Terapia por Luz de Baja Intensidad/métodos , Ultrasonografía , Dolor , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA